Login Register
English
0

Cart

$ 0

CheKine™ Micro GGT Activity Assay Kit: Your Buyer's Guide for Hepatobiliary Biomarker Quantification

Date:2026-08-14 Views:14

The 30-Second Verdict

Gamma-glutamyl transpeptidase (GGT) is the gatekeeper of glutathione metabolism, orchestrating amino acid transport, detoxifying electrophiles, and serving as a critical biomarker for hepatobiliary injury, pancreatic dysfunction, and metabolic syndrome[reference:40]. Abbkine's CheKine™ Micro Gamma-Glutamyl Transpeptidase (GGT) Activity Assay Kit (KTB1690) delivers exceptional value at $49 per kit—far below premium alternatives that can cost three times as much for the same number of tests[reference:41].

Pros

✅ Direct pNA monitoring — avoids GSH/GSSG interference by measuring product formation (405 nm)[reference:42]

✅ Microscale format — just 5–10 µL sample input[reference:43]

✅ Exceptional sensitivity — detection limit of 0.05 U/L (12x more sensitive than Sigma-Aldrich MAK116)[reference:44]

✅ Dynamic range — 0.1–50 U/L[reference:45]

✅ Rapid kinetics — 15-minute incubation at 37°C (vs. 30–60 mins for competitors)[reference:46]

✅ Anti-interference buffer — bilirubin oxidase + hemoglobin scavengers + BSA[reference:47]

✅ Broad sample compatibility — serum, plasma, liver/kidney homogenates, bile, cell lysates[reference:48]

✅ Matrix resilience — validated in samples with bilirubin, hemoglobin, and lipids[reference:49]

Cons

❌ Requires -20°C storage for some components

❌ Not for clinical diagnosis (research use only)

❌ Requires a microplate reader capable of 405 nm absorbance

Who Should Buy This Kit?

Ideal for:

  • Hepatology researchers studying alcoholic liver disease, cholestasis, and drug-induced hepatotoxicity[reference:50]
  • Cardiologists investigating GGT as a cardiovascular risk predictor[reference:51]
  • Cancer biologists tracking GGT in tumor progression[reference:52]
  • Metabolic syndrome researchers
  • Labs working with rare patient sera or tiny tissue biopsies[reference:53]

Skip this if:

  • You lack a microplate reader with 405 nm capability
  • You need to measure total antioxidant capacity (use TAC assays instead)

How It Works: The Enzyme-Coupled Kinetic Design

Unlike kits measuring GGT indirectly (prone to GSH cross-reactivity), KTB1690 uses a direct two-step cascade: GGT transfers γ-glutamyl groups from L-γ-glutamyl-p-nitroanilide (substrate) to glycylglycine (acceptor), releasing p-nitroaniline (pNA)—a yellow product measured at 405 nm, with absorbance proportional to GGT activity[reference:54].

Critical Application Examples

  • Healthy serum: 10–40 U/L[reference:55]
  • Alcoholic hepatitis: 200–500 U/L[reference:56]
  • Single 1-mm liver punch: ≈5 µL extract without dilution error—something legacy kits can't touch[reference:57]

The Bottom Line

For researchers investigating hepatobiliary disease, cardiovascular risk, or drug-induced liver injury, KTB1690 delivers the sensitivity (0.05 U/L), speed (15 minutes), and affordability ($49) that modern biomarker research demands—without the sample waste or interference headaches of traditional kits.

👉 Quantify GGT activity with confidence. View Product