One-step TUNEL Apoptosis Assay Kit (Red Fluorescence) (KTA2011): 555/565 nm and Components Compared

Date:2026-11-27 Views:33

Green channels get crowded. When a TUNEL readout has to sit alongside other fluorescent markers, the emission window becomes a design decision.

The One-step TUNEL Apoptosis Assay Kit (Red Fluorescence) (KTA2011) detects DNA fragmentation through TdT-mediated labeling of nicks generated during apoptosis. The page states the signal is detected at Ex/Em = 555 nm/565 nm and that the kit provides all essential components with an optimized protocol suitable for a fluorescence microplate reader, fluorescence microscope, or flow cytometer.

Red-Fluorescence TUNEL at 555/565 nm

The stated excitation and emission pair is the defining specification.

TUNEL labeling relies on the presence of DNA nicks recognized by TdT, which catalyzes the addition of labeled dUTPs to the 3′-hydroxyl termini of double-strand breaks formed during apoptosis. In this format the signal is read at 555 nm excitation and 565 nm emission. The page lists this value both in the applications note and under Features & Benefits, making the optical requirement explicit for instrument setup.

Eleven Components, Including a Quencher

The kit is supplied as a full panel rather than a core labeling pair.

Components listed are TdT Enzyme, Equilibration Buffer (5×), Label Mix Red, Probe Diluent, DAPI (500×), BSA Working Solution, Triton X-100 (100%), DNase I (5 U/µL), 10×DNase I Buffer, Proteinase K (20 mg/mL), and Tissue Autofluorescence Quencher. The DNase I supports a positive-treatment control, and the quencher is aimed at tissue autofluorescence — a practical consideration when the sample is a section rather than a cell culture. Formats are 20T, 50T, and 100T.

Three Readout Platforms From One Protocol

Plate reader, microscope, and cytometer are all named as compatible.

The applications note states the optimized assay protocol is suitable for a fluorescence microplate reader, fluorescence microscope, or flow cytometer. That means the same labeling reaction can support a quantitative screen, a morphological check, and a population analysis without changing detection chemistry. The figure shows fluorescence signals in HeLa cells treated with 10 U/mL DNase I for 10 minutes.

Buffer Safety and Storage

The reaction buffer carries a handling requirement worth planning for.

The usage note states that the buffer contains cacodylate and cobalt chloride, "highly toxic chemicals," and directs users to rinse affected skin with plenty of water, seek medical advice if feeling unwell, and avoid eating, drinking, or smoking during use. Storage is at least 12 months at -20°C from shipment; once opened, individual components follow the supplied materials list. Shipping is on a gel pack with blue ice.

FeatureThis ProductConventional / typical approach
Detection channelEx/Em = 555 nm/565 nmvaries by fluorophore choice
Component count11 listed components, including DNase I and tissue autofluorescence quencheroften supplied as a smaller core set
Compatible platformsPlate reader, fluorescence microscope, flow cytometercommonly optimized for one readout
Reference treatmentDNase I at 5 U/µL supplied; 10 U/mL for 10 min shown in HeLa cellsoften prepared separately
StorageAt least 12 months at -20°C from shipmentvaries by enzyme format

When the assay needs a red-channel TUNEL signal and a component set that covers both controls and tissue autofluorescence, KTA2011 is worth evaluating on the product page. Confirm the optical filters and the safety handling before the first run.