EliKine™ Progesterone ELISA Kit (Cat. No. KTE0002): Range, Sensitivity, Specificity Compared

Small-molecule steroids do not form the kind of paired antibody sandwich a protein target does. Competitive ELISA is the standard workaround, but a usable result still depends on where the calibration curve sits and how the antibody behaves toward related molecules.
The EliKine™ Progesterone ELISA Kit (Cat. No. KTE0002) is a quantitative competitive ELISA with a colorimetric readout. The supplied microplate is pre-coated with goat-anti-rabbit antibody. Standards or samples are added with a progesterone-specific antibody and HRP-conjugated progesterone; the competition between labeled and unlabeled progesterone produces a color that develops in the opposite direction to the progesterone concentration. The page lists a calibration range of 0.5 ng/ml–30 ng/ml, a limit of detection of 0.2 ng/ml, and a working time of 3–4 hours that depends on operator experience. Reactivity is listed for ten species, including bovine, chicken, human, rat, and swine.
A 0.5–30 ng/ml Range Defines the Working Window
The stated calibration range is 0.5 ng/ml–30 ng/ml. Samples are read against the standards supplied in the kit.
In a competitive assay, the usable window matters as much as the detection limit: a sample that falls outside the standard curve has to be diluted or concentrated before it can be reported. The product page states the limit of detection separately at 0.2 ng/ml, so the bottom of the curve and the detection threshold are not the same number. Listed sample types are serum, plasma, and other biological fluids. Checking expected concentrations against the stated range before starting saves both plate space and sample.
Specificity Is Backed by a Cross-Reactivity Statement
The page makes a direct specificity statement. It reports that no significant cross-reactivity or interference was observed between progesterone and analogues.
That matters for a steroid assay, where structurally related molecules are the usual source of misleading signal. Abbkine describes the kit as having high sensitivity and specificity for progesterone detection, and the competitive reaction uses an antibody specific for progesterone together with HRP-conjugated progesterone. The alternative names listed are pregn-4-ene-3,20-dione and P4, useful when cross-checking catalogs or literature.
A Pre-Coated Plate Keeps Setup Short
The microplate arrives pre-coated with goat-anti-rabbit antibody. The listed working time is 3–4 hours.
A pre-coated plate removes one coating step from the protocol. The kit components listed are progesterone microplate, progesterone standard, HRP conjugated progesterone, progesterone detect antibody, HRP substrate A, HRP substrate B, stop solution, wash buffer, and plate covers. Unopened kits are stored at 2–8 °C and shipped with a gel pack and blue ice. The page advises letting all reagents warm to room temperature for at least 30 minutes before opening, not mixing components from different kit lots, and using fresh pipet tips.
| Feature | This Product | Conventional / typical approach |
|---|---|---|
| Assay format | Competitive ELISA, quantitative, colorimetric | commonly requires a labeled competitor of its own |
| Calibration range | 0.5 ng/ml–30 ng/ml | varies by assay and protocol |
| Limit of detection | 0.2 ng/ml | varies by assay and protocol |
| Working time | 3–4 hours, depending on operator experience | multi-step handling is common |
| Cross-reactivity | No significant cross-reactivity or interference with analogues observed | each antibody and sample set needs its own check |
If your samples are serum, plasma, or other biological fluids and expected progesterone levels fall inside 0.5 ng/ml–30 ng/ml, this kit gives you a published range and detection limit to build a protocol around. Review the full product page before setting up the plate: https://www.abbkine.com/product/elikine-human-progesterone-elisa-kit-kte0002/
Reference: https://www.abbkine.com/product/elikine-human-progesterone-elisa-kit-kte0002/
For research use only. Not for diagnostic or therapeutic use.