Product name | Annexin V-FITC/PI Apoptosis Detection kit |
SampleType | Cells |
Alternative | Annexin V |
Kit components | • Annexin V Binding Buffer (5×) • Annexin V-FITC •Propidium Iodide (PI) •Apoptosis Inducer A •Apoptosis Inducer B |
Features & Benefits | The verified samples are complete in type and easy to operate. |
Usage notes | • If not assayed immediately, samples can be stored at -80°C for one month.• It is recommended to perform several dilutions of your sample to ensure the readings are within the standard value range.• Fresh samples are necessary for good results. If don't perform the assay at the same time, it's better to complete the Sample Preparation step before storing the samples. |
Storage instructions | Storage at -20°C and Keep from light immediately upon receipt. Kit has a storage time of 6 months from receipt. Refer to list of materials supplied for storage conditions of individual components. |
Shipping | Gel pack with blue ice. |
Precautions | The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product. |
Background | Apoptosis is a form of programmed cell death to remove unwanted, damaged, or senescent cells from tissues. In normal cells, the negative phospholipids reside on the inner side of the cellular membrane while the outer surface of the membrane is occupied by uncharged phospholipids (PS). After a cell has entered apoptosis, the negatively charged PS are transported from the inner to the outer leaflet of the plasma membrane, thus exposing PS to the external cellular environment. The human anticoagulant, AnnexinV, is a 35-36 kDa Ca2+ dependent phospholipid-binding protein that has a high affinity for PS. Annexin V labeled with a fluorophore or biotin can identify apoptotic cells by binding to PS exposed on the outer leaflet. Propidium iodide (PI) is a fluorescent nucleus dye, impermeant to live cells and apoptotic cells, but stains dead cells with red fluorescence, binding tightly to the nucleic acids in the cell. Annexin V-FITC/PI Apoptosis Detection kit provides a rapid and convenient assay for apoptosis. After staining a cell population with Annexin V-FITC/PI in the provided binding buffer, early apoptotic cells show green fluorescence of the cellular membrane, dead cells show red fluorescence of the nucleus and green fluorescence of the cellular membrane, and live cells show little or no fluorescence. In addition, to address the non-standardization of apoptosis detection and results, the kit also provides a patented positive reference substance for apoptosis. Detection can be analyzed by flow cytometry or by fluorescence microscopy. |
Alternative | Annexin V |
Fig.Annexin V-FITC/PI Apoptosis Detection kit
You must be logged in to post a review.
1.The species of antibody reactivity should be the sample species that can be matched normally after Abbkine R&D experts have passed strict scientific verification. If your sample is not within the range of reactivity, in order to improve the efficiency and results of your experiment, it is not suggested to try other species. Otherwise, it may lead to sample mismatch and affect the effect of your experiment.
2.Please aliquot the antibody received as soon as possible and store it at -20℃, avoid repeated freezing and thawing, and use it within one year.
Welcome any form of communications, and better service will be provided here.
Tell: +1-404-854-0155
Email: service@abbkine.com
Support Email: support@abbkine.com
Address: 3052 Stroop Hill Road, Apt 203, Atlanta 30303, Georgia, United States of America
Reviews
There are no reviews yet.