Login Register
English
0

Cart

$ 0

Mouse Thrombopoietin receptor (MPL) ELISA Kit

Mouse Thrombopoietin receptor (MPL) ELISA Kit

Views(216) Publications(0) Catalog no(KTE70976)
Datasheet Print Share Email Share
  • Specification
  • FAQ
  • Publications(0)
  • Comments(0)

Specification

Product name Mouse Thrombopoietin receptor (MPL) ELISA Kit
Reactivity Mouse
Applications ELISA
Applications notes This Mouse Thrombopoietin receptor (MPL) ELISA Kit employs a two-site sandwich ELISA to quantitate MPL in samples. An antibody specific for MPL has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyMPL present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MPL is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MPL bound in the initial step. The color development is stopped and the intensity of the color is measured.
Detection method Colorimetric
SampleType Cell culture supernatants, Other biological fluids, Plasma, Serum
Assay type Sandwich ELISA (quantitative)
Assay duration Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.
Alternative MPL; RP1-92O14.1; C-MPL; CD110; MPLV; TPOR; thrombopoietin receptor

Product Properties

Kit components • Mouse Thrombopoietin receptor microplate
• Mouse Thrombopoietin receptor standard
• Mouse Thrombopoietin receptor detect antibody
• Streptavidin-HRP
• Standard diluent
• Assay buffer
• HRP substrate
• Stop solution
• Wash buffer
• Plate covers
Features & Benefits Mouse Thrombopoietin receptor (MPL) ELISA Kit has high sensitivity and excellent specificity for detection of Mouse MPL. No significant cross-reactivity or interference between Mouse MPL and analogues was observed.
Calibration range Please inquire
Limit of detection Please inquire
Usage notes • Do not mix components from different kit lots or use reagents beyond the kit expiration date.
• Allow all reagents to warm to room temperature for at least 30 minutes before opening.
• Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
• Unused wells must be kept desiccated at 4 °C in the sealed bag provided.
• Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
• It is recommended that all samples and standards be assayed in duplicate or triplicate.
Storage instructions The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.
Shipping Gel pack with blue ice.
Precautions The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.

Additional Information

Background In 1990 an oncogene, v-mpl, was identified from the murine myeloproliferative leukemia virus that was capable of immortalizing bone marrow hematopoietic cells from different lineages. In 1992 the human homologue, named, c-mpl, was cloned. Sequence data revealed that c-mpl encoded a protein that was homologous with members of the hematopoietic receptor superfamily. Presence of anti-sense oligodeoxynucleotides of c-mpl inhibited megakaryocyte colony formation. The ligand for c-mpl, thrombopoietin, was cloned in 1994. Thrombopoietin was shown to be the major regulator of megakaryocytopoiesis and platelet formation. The protein encoded by the c-mpl gene, CD110, is a 635 amino acid transmembrane domain, with two extracellular cytokine receptor domains and two intracellular cytokine receptor box motifs . TPO-R deficient mice were severely thrombocytopenic, emphasizing the important role of CD110 and thrombopoietin in megakaryocyte and platelet formation. Upon binding of thrombopoietin CD110 is dimerized and the JAK family of non-receptor tyrosine kinases, as well as the STAT family, the MAPK family, the adaptor protein Shc and the receptors themselves become tyrosine phosphorylated.
Gene ID 17480
Alternative MPL; RP1-92O14.1; C-MPL; CD110; MPLV; TPOR; thrombopoietin receptor
Accession Q08351

Image & description

Fig.1. Mouse Thrombopoietin receptor (MPL) Standard Curve.

Fig.1. Mouse Thrombopoietin receptor (MPL) Standard Curve.

Fig.2. Abbkine ELISA kit is series of sandwich ELISA to quantitate specific protein in samples.

Fig.2. Abbkine ELISA kit is series of sandwich ELISA to quantitate specific protein in samples.

This product has been cited in0publications

Reviews

There are no reviews yet.

Be the first to review “Mouse Thrombopoietin receptor (MPL) ELISA Kit”