Product name | Apoptosis Assay Cocktail |
Applications notes | Apoptosis detection cocktail can detect both early and late apoptosis stages, and it includes a positive reference substance, it’s suitable for different samples, such as tissue and cell. |
Kit components | • Annexin V-AbFluor™ 488 Apoptosis Detection kit (Green Fluorescence)-40T Annexin V Binding Buffer (5x) Annexin V- AbFluor™ 488 Propidium Iodide (PI) • TUNEL Apoptosis Detection Kit (Green Fluorescence)-20T TdT Enzyme Equilibration Buffer (5 x) Label Mix Green Triton X-100 ( 100% ) BSA Working Solution DAPI (500 x) •Positive control-20T Apoptosis Inducer A Apoptosis Inducer B |
Features & Benefits | • High sensitivity • -- Sensitive detection of cell apoptosis at all stages. • Results Standardized results • -- Provided positive control for apoptosis. • Universal • -- Cell samples and tissue samples detection. |
Storage instructions | Refer to list of materials supplied for storage conditions of individual components. |
Shipping | Gel pack with blue ice. |
Precautions | The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product. |
Background | Apoptotic cells undergo a number of important changes, including cell shrinkage, cytoplasmic agglutination, DNA disruption, and formation of membrane vesicles, leading to the separation of cell components to form apoptotic bodies, which are then phagocytic by macrophages or parenchyma cells. The Apoptosis Detection Kit detects apoptosis based on changes in phosphatidylserine (PS) turnover of cell membrane and nuclear rupture. |
Fig.1. Annexin V-AbFluor 488 Apoptosis Detection Kit was used to detect the apoptosis effect of HeLa cells after apoptosis induction
Fig.2.Apoptosis rate was detected with Flow cytometry.
Before preparing the TdT labeling reaction buffer, equilibrate each component to room temperature. The Equilibration Buffer (5×) stock solution may be separated due to low temperature storage. Please invert and mix well before use.
Both TUNEL and Annexin experiments can used A and B inducer. Its purpose is to induce apoptosis, which can be used alone or in combination. Both A and B can induce apoptosis in some common cells. A and B complement each other and can induce apoptosis in more types of cells.
Cell fixation is required, and antigen retrieval is not required. This product marks the DNA fragmented in the nucleus caused by apoptosis, rather than antigenic proteins.
It is recommended to wash at least 2-3 times, because there are many impurities in the medium, which will stick to the cell membrane. After washing, centrifuge well and remove the supernatant with care.
Wash at room temperature at an interval of 5 minutes at a time.
You must be logged in to post a review.
1.The species of antibody reactivity should be the sample species that can be matched normally after Abbkine R&D experts have passed strict scientific verification. If your sample is not within the range of reactivity, in order to improve the efficiency and results of your experiment, it is not suggested to try other species. Otherwise, it may lead to sample mismatch and affect the effect of your experiment.
2.Please aliquot the antibody received as soon as possible and store it at -20℃, avoid repeated freezing and thawing, and use it within one year.
Welcome any form of communications, and better service will be provided here.