Human Ensconsin (MAP7) ELISA Kit

Product Information

  • Product name

    Human Ensconsin (MAP7) ELISA Kit

  • Reactivity

    Human

  • Applications

    ELISA

  • Application notes

    This Human Ensconsin (MAP7) ELISA Kit employs a two-site sandwich ELISA to quantitate MAP7 in samples. An antibody specific for MAP7 has been pre-coated onto a microplate. Standards and samples are pipetted into the wells and anyMAP7 present is bound by the immobilized antibody. After removing any unbound substances, a biotin-conjugated antibody specific for MAP7 is added to the wells. After washing, Streptavidin conjugated Horseradish Peroxidase (HRP) is added to the wells. Following a wash to remove any unbound avidin-enzyme reagent, a substrate solution is added to the wells and color develops in proportion to the amount of MAP7 bound in the initial step. The color development is stopped and the intensity of the color is measured.

  • Detection method

    Colorimetric

  • Sample type

    Cell culture supernatants, Other biological fluids, Plasma, Serum

  • Assay type

    Sandwich ELISA (quantitative)

  • Assay duration

    Multiple steps standard sandwich ELISA assay with a working time of 3-5 hours. It depends on the experience of the operation person.

Fig.1. Human Ensconsin (MAP7) Standard Curve.

Fig.2. Abbkine ELISA kit is series of sandwich ELISA to quantitate specific protein in samples.

Product Properties

  • Kit components

    • Human Ensconsin microplate
    • Human Ensconsin standard
    • Human Ensconsin detect antibody
    • Streptavidin-HRP
    • Standard diluent
    • Assay buffer
    • HRP substrate
    • Stop solution
    • Wash buffer
    • Plate covers

  • Features & Benefits

    Human Ensconsin (MAP7) ELISA Kit has high sensitivity and excellent specificity for detection of Human MAP7. No significant cross-reactivity or interference between Human MAP7 and analogues was observed.

  • Calibration range

    37.5-2400 pg/mL

  • Limit of detection

    38.37 pg/mL

  • Usage notes

    • Do not mix components from different kit lots or use reagents beyond the kit expiration date.
    • Allow all reagents to warm to room temperature for at least 30 minutes before opening.
    • Pre-rinse the pipet tip with reagent, use fresh pipet tips for each sample, standard and reagent to avoid contamination.
    • Unused wells must be kept desiccated at 4 °C in the sealed bag provided.
    • Mix Thoroughly is very important for the result. It is recommended using low frequency oscillator or slight hand shaking every 10 minutes.
    • It is recommended that all samples and standards be assayed in duplicate or triplicate.

  • Storage instructions

    The unopened kit should be stored at 2 - 8°C. After opening, please store refer to protocols.

  • Shipping

    Gel pack with blue ice.

  • Precautions

    The product listed herein is for research use only and is not intended for use in human or clinical diagnosis. Suggested applications of our products are not recommendations to use our products in violation of any patent or as a license. We cannot be responsible for patent infringements or other violations that may occur with the use of this product.

Additional Information

  • Background

    Ensconsin is a microtubule-associated protein that is predominantly expressed in cells of epithelial origin. Microtubule-associated proteins are thought to be involved in microtubule dynamics, which is essential for cell polarization and differentiation. This protein has been shown to be able to stabilize microtubules, and may serve to modulate microtubule functions. Studies of the related mouse protein also suggested an essential role in microtubule function required for spermatogenesis. Expressed in the skin and cells of epithelial origin. Predominantly expressed in the suprabasal layers of the normal epidermis and relatively abundant in squamous cell carcinomas but barely detectable in basal cell carcinomas.

  • Gene ID

    9053

  • Alternative names

    MAP7; E-MAP-115; EMAP115; dJ325F22.2 (microtubule-associated protein 7 (EMAP115; E-MAP-115))

  • Accession

    Q14244

Most popular with customers

Reviews

There are no reviews yet.

Be the first to review “Human Ensconsin (MAP7) ELISA Kit”

Your email address will not be published. Required fields are marked *

Human Ensconsin (MAP7) ELISA Kit
Click to download booklet for more details

Here we provide some standard research protocols for bioscience including molecular biology, cell biology, immunology, plant biology, genetics, etc. To our knowledge, customized protocols are not required for most products. So please try the standard protocols listed below and let us know how you get on.

Preparation methods for Biochemical

Biochemical reagents have been widely used in life science fundamental research as buffer, probes, substrates, intermediates and standards, etc. You may optimize or choose proper protocols for your specific assay. However, some of tips and suggestions listed below may be for your reference.

  1. ♦ What and how to make a "good" buffer?

Antibody application protocols

Antibodies are useful not only to detect specific biomolecules but also to measure changes in their level and specificity of modification by processes such as phosphorylation, methylation, or glycosylation. Here show some protocols and troubleshooting tips on how to get the best from our antibodies.

  1. ♦ Antibody Western Blotting (WB) protocol
  2. ♦ Antibody Immunohistochemistry (IHC) protocol
  3. ♦ Antibody Immunofluorescence (IF) protocol
  4. ♦ Antibody Immunoprecipitation (IP) protocol
  5. ♦ Antibody Enzyme-Linked ImmunoSorbent Assay (ELISA) protocol

Protein&peptide usage suggestions

Synthetic peptides, native or recombinant proteins can be used for medical, academic and research purposes, such as gene therapy, drug screening, antibody production, cell function analysis. Here, we provide some of tips and suggestions for your reference.

  1. ♦ Handling and storage suggestion for peptides and protein
  2. ♦ Cytokines and growth factors for cell culture application

Commonly used assay kits guidelines

Assay kits that are simple and convenient to use, which are superior in performance and require little to no time for assay optimization. Further details of specific products which are needed for individual protocols are given in the protocols themselves in booklet.

We hope this will be helpful for your research work. Please let us know through support@abbkine.com if you need more information or support.

Cat #: KTE61737

  • Size
  • Price
  • 48T $260
  • 96T $450
  • 96T*5 $2025
  • 96T*50 $18900

Contact information

Do not hesitate to contact us if you have any questions.

  •  Customer: service@abbkine.com
  •  Message: Click to Leave
  •  Tel: +86-27-59716789
  •  Fax: +86-27-59716788
  • Global Headquarters: Bldg 1, Harbour of Technology Times, No.35, Optical Valley Ave, Wuhan, Hubei, China. 430074

Gaining Your Trust with our

High quality *
Attractive price
100% Guarantee
Secured shipment